159 research outputs found

    Possibilities of holographic techniques in laser scanning microscopy

    Get PDF
    Holographic scanning microscopy-novel technique both in laser scanning microscopy and digital holographic microscopy allow multimodal approach to cell and tissue investigation in biomedical applications promising new advantages (quantitative phase imaging, superresolution, computerized tomography), but regular reconstruction leads to incorrectness. Analysis of light propagation through the schematics allows to offer reconstruction procedures depending on recording conditions

    Hyperspectral system for Imaging of skin chromophores and blood oxygenation

    Get PDF
    We developed a compact, fast, hand-held hyperspectral imaging system for 2D neural network-based visualization of skin chromophores and blood oxygenation. Here, we present results of the system tests on healthy volunteers

    Multiple scattering of light in optical diagnostics of dense sprays and other complex turbid media

    Get PDF
    Sprays and other industrially relevant turbid media can be quantitatively and qualitatively characterized using modern optical diagnostics. However, current laser based techniques generate errors in the dense region of sprays due to the multiple scattering of laser radiation e ected by the surrounding cloud of droplets. In most industrial sprays, the scattering of light occurs within the so-called intermediate scattering regime where the average number of scattering events is too great for single scattering to be assumed, but too few for the di usion approximation to be applied. An understanding and adequate prediction of the radiative transfer in this scattering regime is a challenging and non-trivial task that can significantly improve the accuracy and e ciency of optical measurements. A novel technique has been developed for the modelling of optical radiation propagation in inhomogeneous polydisperse scattering media such as sprays. The computational model is aimed to provide both predictive and reliable information, and to improve the interpretation of experimental results in spray diagnostics. Results from simulations are verified against the analytical approach and validated against the experiment by the means of homogeneous solutions of suspended polystyrene spheres. The ability of the technique to simulate various detection conditions, to di erentiate scattering orders and to generate real images of light intensity distributions with high spatial resolution is demonstrated. The model is used for the real case of planar Mie imaging through a typical hollow cone water spray. Versatile usage of this model is exemplified with its applications to image transfer through turbid media, correction of experimental Beer-Lambert measurements, the study of light scattering by single particles in the farfield region, and to simulate the propagation of ultra-short laser pulses within complex scattering media. The last application is fundamental for the development and testing of future optical spray diagnostics; particularly for those based on time-gating detection such as ballistic imaging.EThOS - Electronic Theses Online ServiceGBUnited Kingdo

    Biophotonics methods for functional monitoring of complications of diabetes mellitus

    Get PDF
    The prevalence of diabetes complications is a significant public health problem with a considerable economic cost. Thus, the timely diagnosis of complications and prevention of their development will contribute to increasing the length and quality of patient life, and reducing the economic costs of their treatment. This article aims to review the current state-of-the-art biophotonics technologies used to identify the complications of diabetes mellitus and assess the quality of their treatment. Additionally, these technologies assess the structural and functional properties of biological tissues, and they include capillaroscopy, laser Doppler flowmetry and hyperspectral imaging, laser speckle contrast imaging, diffuse reflectance spectroscopy and imaging, fluorescence spectroscopy and imaging, optical coherence tomography, optoacoustic imaging and confocal microscopy. Recent advances in the field of optical noninvasive diagnosis suggest a wider introduction of biophotonics technologies into clinical practice and, in particular, in diabetes care units

    Towards enhanced optical sensor performance:SEIRA and SERS with plasmonic nanostars

    Get PDF
    We report the preparation and characterization of plasmonic chip-based systems comprising self-assembled gold nanostars at silicon substrates that enable concomitantly enhanced Raman (surface enhanced Raman spectroscopy; SERS) and mid-infrared (surface enhanced infrared reflection or absorption spectroscopy; SEIRA) spectral signatures. The high-aspect-ratio structure of gold nanostars provides an increased number of hot spots at their surface, which results in an electric field enhancement around the nanomaterial. Gold nanostars were immobilized at a silicon substrate via a thin gold layer, and α-ω-dimercapto polyethylene glycol (SH-PEG-SH) linkers. The Raman and IR spectra of crystal violet (CV) revealed a noticeable enhancement of the analyte vibrational signal intensity in SERS and SEIRA studies resulting from the presence of the nanostars. Enhancement factors of 2.5 × 10 3 and 2.3 × 10 3 were calculated in SERS considering the CV bands at 1374.9 cm -1 and 1181 cm -1 , respectively; for SEIRA, an enhancement factor of 5.36 was achieved considering the CV band at 1585 cm -1

    Circular polarization memory in polydisperse scattering media

    Get PDF
    We investigate the survival of circularly polarized light in random scattering media. The surprising persistence of this form of polarization has a known dependence on the size and refractive index of scattering particles, however a general description regarding polydisperse media is lacking. Through analysis of Mie theory, we present a means of calculating the magnitude of circular polarization memory in complex media, with total generality in the distribution of particle sizes and refractive indices. Quantification of this memory effect enables an alternate pathway toward recovering particle size distribution, based on measurements of diffusing circularly polarized light

    Speckle dynamics under ergodicity breaking

    Get PDF
    Laser speckle contrast imaging (LSCI) is a well-known and versatile approach for the non-invasive visualization of flows and microcirculation localized in turbid scattering media, including biological tissues. In most conventional implementations of LSCI the ergodic regime is typically assumed valid. However, most composite turbid scattering media, especially biological tissues, are non-ergodic, containing a mixture of dynamic and static centers of light scattering. In the current study, we examined the speckle contrast in different dynamic conditions with the aim of assessing limitations in the quantitative interpretation of speckle contrast images. Based on a simple phenomenological approach, we introduced a coefficient of speckle dynamics to quantitatively assess the ratio of the dynamic part of a scattering medium to the static one. The introduced coefficient allows one to distinguish real changes in motion from the mere appearance of static components in the field of view. As examples of systems with static/dynamic transitions, thawing and heating of Intralipid samples were studied by the LSCI approach

    Performance and flow dynamics studies of polymeric optofluidic sers sensors

    Get PDF
    We present a polymer-based optofluidic surface enhanced Raman scattering chip for biomolecule detection, serving as a disposable sensorchoice with cost-effective production. The SERS substrate is fabricated by using industrial roll-to-roll UV-nanoimprinting equipment andintegrated with adhesive-based polymeric microfluidics. The functioning of the SERS detection on-chip is confirmed and the effect of thepolymer lid on the obtainable Raman spectra is analysed. Rhodamine 6G is used as a model analyte to demonstrate continuous flowmeasurements on a planar SERS substrate in a microchannel. The relation between the temporal response of the sensors and sample flowdynamics is studied with varied flow velocities, using SERS and fluorescence detection. The response time of the surface-dependent SERSsignal is longer than the response time of the fluorescence signal of the bulk flow. This observation revealed the effect of convection on thetemporal SERS responses at 25 μl/min to 1000 μl/min flow velocities. The diffusion of analyte molecules from the bulk concentration intothe sensing surface induces about a 40-second lag time in the SERS detection. This lag time, and its rising trend with slower flow velocities, has to be taken into account in future trials of the optofluidic SERS sensor, with active analyte binding on the sensing surface

    The influence of local pressure on evaluation parameters of skin blood perfusion and fluorescence

    Get PDF
    This article presents the results of the study of the pressure applied on optical diagnostic probes as a significant factor affecting the results of measurements. During stepwise increasing and decreasing of local pressure on skin we conducted measurements using the methods of laser Doppler flowmetry and fluorescence spectroscopy. It was found out that pressure on optical probe has sufficient impact on skin microcirculation to affect registered fluorescence intensity. Data obtained in this study are of interest for design and development of diagnostic technologies for wearable devices. This data will also inform further investigation into issues of compensation of blood absorption influence on fluorescence spectrum, allowing increased accuracy and reproducibility of measurements by fluorescence spectroscopy methods in optical diagnosis

    Non-invasive control of influence of polyethylene glycol on transport function of fluorescent colored liposomal nanoparticles

    Get PDF
    The studies were carried out on groups of clinically healthy mice line of outbred CD-1 stock. The model animals were divided into 2 groups and received experimental liposomal formulations. Using the method of fluorescence spectroscopy, we investigated the effectiveness of penetration into the circulatory system of fluorescently stained liposomes with polyethylene glycol (PEG) and without PEG when administered orally. Fluorescence channel with a fiber probe series of multifunctional laser non-invasive diagnostic system "LAKK-M" (SPE "LAZMA" Ltd, Russia) was used as the measuring equipment
    corecore